Start with the Loads Being Served

A power panelboard distributes circuits to motors, process equipment, HVAC systems, receptacles, or other facility loads. Begin selection with an accurate load schedule: identify each connected device, voltage and phase, full-load current, starting characteristics, duty cycle, and whether the load is continuous. These details shape feeder sizing and circuit allocation.

Separate existing loads from planned additions, and note which equipment operates together. A panelboard’s usable capacity depends on the electrical design, not simply the number of spaces in its enclosure. Have the responsible engineer establish demand assumptions and applicable code requirements rather than relying on a rough connected-load total.

Confirm System Voltage and Supply

Document the source system, including nominal voltage, phase, frequency, grounding arrangement, and available feeder conductors. Confirm whether the panelboard will be supplied from a transformer, switchboard, switchgear, or another distribution point, and record the source overcurrent device. These relationships affect bus configuration, main-device selection, and installation details.

The panelboard’s voltage and short-circuit ratings must be suitable for the system and the available fault current at its location. Ask the engineer to verify fault-current calculations and protective-device coordination using project data. Utility information may be needed upstream; the authority having jurisdiction reviews compliance with applicable requirements.

Choose Main and Feeder Arrangements

A panelboard may use a main circuit breaker, main lugs supplied by an upstream protective device, or another arrangement appropriate to the design. Compare these options with the feeder source, required local isolation, available space, maintenance practices, and the project’s protection scheme. Confirm whether a separate disconnect is required at the installation point.

Feeder circuits from the panelboard can supply downstream distribution equipment or larger loads, while branch circuits typically serve individual loads or groups of smaller loads. Define the purpose and expected current of each outgoing circuit. The engineer should check conductor ampacity, overcurrent protection, voltage drop, and any applicable rules for the specific installation.

Plan Circuit Count and Protective Devices

Build the circuit schedule from actual loads, including poles, amperage, and any special protection required by the equipment or installation. Motor circuits may need coordinated overload and short-circuit protection, while other loads can call for distinct protective-device characteristics. Confirm device compatibility with the proposed panelboard instead of assuming every breaker type is interchangeable.

Include practical spare capacity for anticipated changes, but distinguish spare circuit positions from available electrical capacity. A vacant space does not establish that the bus or feeder can support a future load. Identify any required auxiliary contacts, shunt trips, lockable provisions, or other accessories for the manufacturer to evaluate against the design.

Evaluate Fault Ratings and Coordination

Specify the required short-circuit current rating based on the calculated available fault current and the intended protective-device configuration. Series ratings, if considered, require documented compatibility and must be applied within their stated conditions. Do not infer a panelboard rating from a breaker rating alone; confirm the assembled configuration with the manufacturer.

Coordination studies help determine how protective devices respond to faults across feeder and branch circuits. Provide upstream device details and downstream equipment data where available, and flag selective coordination requirements. The responsible engineer should review the study and confirm the final devices, settings, and ratings meet project criteria before release.

Match the Enclosure to the Location

Describe the installation environment and mounting arrangement: indoor or outdoor location, surface or flush mounting, ambient conditions, available wall space, and access for operation and maintenance. Identify exposure to dust, moisture, corrosive agents, vibration, or temperature extremes. The appropriate enclosure and construction depend on these site conditions and applicable requirements.

Confirm working clearances, cable entry direction, conduit access, and the route for incoming and outgoing conductors. Provide room layout drawings or dimensions when possible, especially where equipment must fit an existing electrical room. Enclosure dimensions, finish, and construction details should be confirmed for the specific project, not assumed from a general product description.

Coordinate Installation and Documentation

A useful submittal package aligns the panelboard schedule with one-line diagrams, feeder information, load descriptions, and installation conditions. Identify the equipment served, panel designation, source, and required circuit labels. Confirm terminal requirements, conductor material and size, entry locations, and any field wiring constraints with the electrical contractor and design team.

Review the proposed configuration before fabrication, including device schedule, bus and main arrangement, enclosure, and accessory requirements. Confirm applicable product standards and project specifications for the particular assembly. Installation, grounding, clearances, and field connections must follow the approved design, manufacturer instructions, and requirements accepted by the AHJ.

Prepare a Complete Equipment Quote Request

For a quote, provide the one-line diagram, panel schedule, system voltage and phase, source protective-device information, available fault current, required ratings, and enclosure location. Include circuit quantities and descriptions, device poles and amperages, main arrangement, mounting style, conductor entry preferences, and project specifications. Note the required delivery destination and schedule constraints.

A U.S. manufacturer can build new power panelboards with American components and custom fabrication, with short lead times and nationwide shipping. The project team should identify any submittal or approval milestones that affect procurement. Final details remain subject to engineering review and confirmation of the specific equipment configuration.

PROJECT PARAMETERS

Details make
the difference.

Every project is different. Use these points as a starting place for a conversation about your requirements.

Discuss your specifications
SPECIFICATION OVERVIEW01 — 06
Project specification overview
Equipment & scopeDefined by project requirements
Voltage classConfirm for the application
Current ratingConfirm for the application
Applicable standardsUL 891 for applicable low-voltage switchboards; other standards per specification
ManufacturingMade in USA with American components
Lead timeQuoted per project

Final configuration, ratings, standards, and timing are confirmed with your quote.

LET'S GET TO WORK

Tell us what
you’re building.

Share the essentials and start a conversation about equipment for your project.

Prefer to talk?(951) 403-5738

Email our team at saleselectricalbuyers@gmail.com.

SWITCHGEAR BUILDERS OHIO
BUILT FOR THE WORK AHEAD

PROJECT INQUIRY

Request a quote

This form opens your email application where supported. Review and send your request to saleselectricalbuyers@gmail.com from your email app; nothing is submitted directly through this website.

* Required fields