Request a Quote

Power distribution equipment

Motor Control Centers

Specify a new motor control center around the motors, feeders, operating environment, and communications it must serve. We build custom equipment in the U.S. with American components and ship nationwide.

01 / BUILT WITH PURPOSE SWITCHGEAR BUILDERS OHIO

Switchgear cabinets in an electrical equipment room
REPRESENTATIVE
EQUIPMENT
01
Made in USAAmerican manufacturing
02
UL 891 assembliesFor applicable low-voltage switchboards
03
Short lead timesTiming quoted per project

Coordinate motor control in one assembly

A motor control center (MCC) groups motor control units and related distribution equipment in a common assembly. It can organize across-the-line starters, drives, soft starters, and feeder units, subject to the project design. Grouping supports coordinated layout and access, but does not make every unit interchangeable or remove the need to specify its function.

Start by documenting each motor’s nameplate voltage, horsepower, full-load current, starting method, duty, and driven load. Include operating sequence and whether motors start together or in stages. These details help determine unit types, bus requirements, feeder arrangement, and control provisions; confirm final selections with the responsible electrical engineer.

Define the incoming supply and bus arrangement

The MCC’s supply conditions shape its bus and incoming section. Confirm system voltage, phase, frequency, available fault current, grounding method, source configuration, and whether the assembly receives power from a transformer or upstream switchboard. Identify any tie, alternate source, or future section requirements rather than assuming they can be accommodated later.

Bus ampacity and short-circuit ratings must suit the system and the applicable assembly construction. Those ratings depend on design and specified conditions; they are not universal attributes of an MCC. The engineer should verify coordination with upstream protection, utility information where applicable, and the authority having jurisdiction (AHJ).

Match motor units to loads and starting needs

Each motor unit needs a defined purpose and protection approach. A starter unit may include a contactor and overload protection; a drive unit may provide adjustable speed and require different input and output considerations. Confirm motor count, operating profile, acceleration needs, reversing or braking functions, and any process limits affecting control.

Across-the-line starting can create a different electrical and mechanical impact from reduced-voltage or variable-frequency starting. Check starting current, voltage drop, load inertia, starts per hour, and the effects on the supply and driven equipment. The responsible engineer and motor supplier should confirm that the selected method fits both the process and electrical system.

Plan feeder protection and coordination

MCCs may combine motor units with feeder units for loads such as panelboards, transformers, or auxiliary equipment. List each feeder’s load, voltage, continuous and noncontinuous demand, conductor arrangement, and required disconnecting means. Decide whether feeder protection is by circuit breaker or fusible device based on the design, coordination objectives, and project requirements.

Protection settings and device selections need review against available fault current, conductor limits, motor starting behavior, and upstream and downstream devices. Selectivity may be a project goal, but its extent depends on the chosen devices and operating conditions. Provide coordination studies and equipment data when available, and have the engineer verify the final scheme.

Specify control power and communications

Control architecture determines how operators and automation systems interact with the MCC. Identify local start-stop stations, interlocks, permissives, status points, alarms, and the intended control-power source. State whether control is hardwired, networked, or a combination, and distinguish control functions required for operation from optional monitoring.

For communications, name the plant network or protocol, controller interface, data points, addressing or integration expectations, and responsibility for configuration. Confirm network hardware, isolation, and cybersecurity requirements with the controls team. Drives and smart protective devices may expose useful data, but available points and integration behavior depend on the selected components.

Fit the lineup to the room and maintenance plan

Room conditions and access affect lineup dimensions, section arrangement, and installation planning. Provide available floor space, ceiling height, door and aisle clearances, cable entry direction, conduit locations, and any overhead obstacles. Confirm ambient temperature, altitude, dust, moisture, corrosive exposure, and ventilation conditions so enclosure and thermal needs can be evaluated for the actual site.

Maintenance preferences may influence unit construction, access, and spare-space planning. Identify whether the project requires withdrawable or fixed units, rear access, provisions for future units, or a specific cable termination approach. These options affect layout and cost; confirm they are feasible with the application and do not assume a standard footprint.

Confirm the applicable equipment standard

An MCC is not simply a switchboard with motor starters added. Determine the intended equipment type and applicable standard for the application; UL 845 is the relevant standard for motor control centers. UL 891 applies to switchboards, while UL 1558 applies to low-voltage switchgear. Medium-voltage equipment is a separate category with different requirements.

Specify the required voltage class, enclosure, access, labeling, and any project documentation or inspection needs. Applicable certification or listing depends on the actual build and scope, so confirm it for the proposed equipment rather than presuming a status. The responsible engineer, owner, and AHJ should resolve standard and installation questions before release.

Prepare a complete request for quotation

A useful quotation package includes a one-line diagram, motor and feeder schedules, load data, system fault information, control narrative, communication requirements, and room drawings. Add the requested quantity, preferred lineup orientation, cable entry, environmental conditions, and any specifications or approved component preferences. Flag unresolved items clearly so assumptions can be identified and reviewed.

We manufacture new motor control centers in the U.S. using American components, with custom fabrication and nationwide shipping. For a project review, share target schedule, delivery destination, required submittals, and the engineer’s contact for technical clarifications. Lead time depends on scope and current requirements; confirm schedule and configuration in the project quotation.

PROJECT PARAMETERS

Details make
the difference.

Every project is different. Use these points as a starting place for a conversation about your requirements.

Discuss your specifications
SPECIFICATION OVERVIEW01 — 06
Project specification overview
Equipment & scopeDefined by project requirements
Voltage classConfirm for the application
Current ratingConfirm for the application
Applicable standardsUL 891 for applicable low-voltage switchboards; other standards per specification
ManufacturingMade in USA with American components
Lead timeQuoted per project

Final configuration, ratings, standards, and timing are confirmed with your quote.

LET'S GET TO WORK

Tell us what
you’re building.

Share the essentials and start a conversation about equipment for your project.

Prefer to talk?(951) 403-5738

Email our team at saleselectricalbuyers@gmail.com.

SWITCHGEAR BUILDERS OHIO
BUILT FOR THE WORK AHEAD

PROJECT INQUIRY

Request a quote

This form opens your email application where supported. Review and send your request to saleselectricalbuyers@gmail.com from your email app; nothing is submitted directly through this website.

* Required fields