Request a Quote

Serving Ohio

Akron Process Manufacturing MCC Units

Plan motor control centers for Akron process facilities around the motor list, operating sequence, and available space. We build new, custom-configured MCC equipment in the U.S. for projects in Ohio and nationwide.

01 / BUILT WITH PURPOSE SWITCHGEAR BUILDERS OHIO

Electrical equipment sections on a flatbed trailer outdoors
REPRESENTATIVE
EQUIPMENT
01
Made in USAAmerican manufacturing
02
UL 891 assembliesFor applicable low-voltage switchboards
03
Short lead timesTiming quoted per project

Start with the process and motor list

An MCC arrangement should follow the process, not simply group motors by horsepower. For an Akron manufacturing project, map each motor to its driven equipment, process area, normal operating mode, and consequence of interruption. Include pumps, conveyors, mixers, fans, and spare loads so the lineup reflects how operators and maintenance teams work.

For a useful equipment review and quote, provide motor nameplate data, voltage, full-load current, horsepower, starting method, and any available fault-current information. Identify loads expected to run together, critical processes, and future additions. The responsible engineer should verify load calculations, protection coordination, and the design basis before equipment is released.

Choose unit arrangements for access and operation

Unit placement affects operator visibility, maintenance access, and the path of process wiring. Grouping units by process area can make identification intuitive, while grouping similar functions may simplify maintenance. Confirm the desired lineup orientation, room entry points, aisle clearances, cable access, and any limits imposed by the existing electrical room.

The arrangement may combine full-height or partial-height sections and different unit sizes, depending on the selected equipment design and load schedule. Confirm which units need local controls, metering, or space for field wiring. Door swing, handle position, wireway capacity, and access for removal should be reviewed against the actual room layout.

Match motor starters to operating duty

Across-the-line starters may suit motors that can tolerate full-voltage starting and the resulting inrush. Reduced-voltage starting or variable-frequency drives may be appropriate when process requirements call for controlled acceleration, speed adjustment, or reduced mechanical stress. Selection depends on the motor, driven load, supply conditions, operating sequence, and the project’s control philosophy.

For each starter, confirm motor data, expected starts per hour, acceleration needs, overload requirements, and whether reversing or jogging is required. A drive or soft starter can alter heat dissipation and space needs within the lineup. Check manufacturer application guidance and have the responsible engineer confirm suitability, coordination, and protection.

Define control wiring at the system boundary

Process control wiring should be designed around clear interfaces between the MCC, PLC or distributed control system, field devices, and operator stations. List the required commands and status points for each motor, including start, stop, running, fault, and available indications where applicable. Distinguish hardwired signals from network communications and identify who supplies each connection.

Provide control schematics, I/O lists, network requirements, and the intended source and voltage of control power. Confirm terminal locations, cable entry, shielding and grounding practices, and whether field interlocks land in the MCC or at another panel. These details avoid assumptions about wiring scope and allow the quote to reflect the required interfaces.

Coordinate protection, fault duty, and supply data

MCC selection depends on the electrical service and the available fault current at the equipment location. Gather system voltage, phase, frequency, grounding method, upstream protective-device information, and the utility or facility fault-current study. Confirm the required short-circuit rating and coordination approach; these values must be established for the specific installation.

Protection choices should account for motor starting, conductor protection, overload response, and selective coordination objectives where required. Do not infer that a particular rating or protective feature applies to every configuration. The electrical engineer should check the design against applicable codes, service conditions, and the authority having jurisdiction before procurement.

Plan heat, environment, and physical installation

Process areas can impose conditions that influence enclosure selection and component placement, including dust, moisture, washdown, corrosive agents, and ambient temperature. Describe the actual installation environment and cleaning practices rather than relying on a general label such as industrial or indoor. Confirm enclosure requirements and any restrictions with the project engineer.

Room dimensions, floor condition, conduit locations, overhead obstructions, and equipment access affect section dimensions and field installation. Identify shipping and handling limits, the intended lineup position, and whether the equipment must interface with existing gear. The manufacturer can review supplied layout information, but site measurements and installation clearances should be verified by the project team.

Prepare a complete RFQ package

A clear request for quotation includes the motor schedule, one-line diagram, control schematics, I/O list, layout, and applicable project specifications. Add service data, fault-current documentation, preferred starter types, communications protocols, and required metering or operator devices. Mark unresolved selections as open items so assumptions can be identified and addressed before release.

Also state the required quantity, requested delivery milestones, shipping destination, and any project documentation or inspection requirements. Identify interfaces with upstream distribution equipment and downstream field wiring, including responsibility for cables and terminations. We build new MCC equipment in the U.S. with American components and offer custom fabrication and nationwide shipping; lead time is confirmed for the project scope.

Review submittals before equipment release

Submittal review is the point to resolve unit sequence, device tags, starter selections, control terminals, communications interfaces, and lineup dimensions. Compare drawings with the latest process and electrical documents, and route changes through the project’s approval process. Check that labels and unit identifiers match the motor list operators will use.

Confirm the specified equipment category and applicable standards for the requested assembly; MCC requirements should not be confused with switchboard or low-voltage switchgear standards. Final design decisions depend on the project, and no particular listing or rating should be assumed for a custom build. The responsible engineer, utility where relevant, and AHJ should review applicable requirements.

PROJECT PARAMETERS

Details make
the difference.

Every project is different. Use these points as a starting place for a conversation about your requirements.

Discuss your specifications
SPECIFICATION OVERVIEW01 — 06
Project specification overview
Equipment & scopeDefined by project requirements
Voltage classConfirm for the application
Current ratingConfirm for the application
Applicable standardsUL 891 for applicable low-voltage switchboards; other standards per specification
ManufacturingMade in USA with American components
Lead timeQuoted per project

Final configuration, ratings, standards, and timing are confirmed with your quote.

LET'S GET TO WORK

Tell us what
you’re building.

Share the essentials and start a conversation about equipment for your project.

Prefer to talk?(951) 403-5738

Email our team at saleselectricalbuyers@gmail.com.

SWITCHGEAR BUILDERS OHIO
BUILT FOR THE WORK AHEAD

PROJECT INQUIRY

Request a quote

This form opens your email application where supported. Review and send your request to saleselectricalbuyers@gmail.com from your email app; nothing is submitted directly through this website.

* Required fields