Request a Quote

Manufacturing capabilities

Switchgear Fabrication

Switchgear fabrication turns an approved electrical design into a buildable enclosure, with coordinated structures, bus supports and compartments. Learn what to specify, verify and provide when requesting a quote.

01 / BUILT WITH PURPOSE SWITCHGEAR BUILDERS OHIO

Switchgear cabinets in an electrical equipment room
REPRESENTATIVE
EQUIPMENT
01
Made in USAAmerican manufacturing
02
UL 891 assembliesFor applicable low-voltage switchboards
03
Short lead timesTiming quoted per project

Fabrication Starts with the Equipment Design

Fabrication planning begins with the equipment’s electrical function and the arrangement of its incoming, distribution and protective devices. The design establishes the lineup dimensions, compartment boundaries, access direction and interfaces with cables or bus duct. These decisions affect sheet-metal patterns, structural members, assembly sequence and usable working space.

Before quoting, provide the one-line diagram, equipment schedule, available layout drawings and applicable project specifications. Identify the intended equipment type and standard, such as a UL 891 switchboard or UL 1558 low-voltage switchgear. Medium-voltage equipment requires a separate design basis; UL 891 does not apply to medium- or high-voltage equipment.

Enclosure Geometry and Site Fit

The enclosure frame and panels must accommodate the specified devices while fitting the installation space. Overall height, width and depth, lineup length, access clearances, conduit entry zones, floor conditions and handling routes can constrain fabrication. Confirm whether cable access is from the top, bottom, front or rear, and whether the lineup must align with adjacent equipment.

Supply room plans, equipment-room elevations and field-verified dimensions when available. Note door swing limits, overhead obstructions, housekeeping pads, seismic or anchorage criteria, and any shipping or rigging limits. These are design inputs to review, not assumed capabilities; the responsible engineer and project team should reconcile site conditions with the equipment arrangement.

Bus Supports Need Electrical and Mechanical Coordination

Bus supports hold conductors in their intended positions and transfer mechanical forces into the structure. Their locations and construction depend on the bus arrangement, phase spacing, bracing requirements, conductor geometry and the design’s fault-current basis. Supports must also preserve required electrical clearances and avoid interference with devices, barriers, cable bends and service access.

A quote package should identify bus material and configuration, system voltage, phase and neutral arrangement, grounding scheme, and specified short-circuit or withstand requirements. Provide the relevant drawings and project standards rather than relying on a generic support assumption. The responsible electrical engineer must verify the design basis and its coordination with protective-device and system information.

Compartments, Barriers and Access

Compartment features can include partitions, device mounting surfaces, doors, covers and openings for wiring or ventilation. Their arrangement depends on the selected equipment and the project’s access and separation requirements. Openings must be coordinated with live-part clearances, cable routing, device operation and maintenance tasks; the exact construction is design-specific, not universal.

Specify which devices or functional sections require separation, what access is needed for operation and service, and whether project documents call for particular barriers or compartment boundaries. Provide control schematics, device schedules and terminal plans when available. Review access and separation expectations with the engineer, owner and applicable authority having jurisdiction before fabrication details are finalized.

Material, Forming and Assembly Choices

Sheet and structural components are cut, formed and assembled to create the enclosure and internal supports. Gauge, reinforcement, seams, fastening methods and finish depend on the design, enclosure dimensions, equipment loads, environment and specified construction requirements. Fabrication details must allow panels and doors to align while maintaining access to installed devices and wiring spaces.

State the required enclosure material and finish, indoor or outdoor application, environmental conditions and any project-specific corrosion or ingress-protection criteria. Identify special colors, labeling conventions and accessory openings. If a specification calls for a particular construction method or approval, include it for review; do not assume every option is part of a standard build or applicable to every product type.

Device Layout Drives Fabrication Details

Breaker frames, switches, metering, control devices and terminal sections determine cutouts, mounting patterns, reinforcing and internal clearances. Their exact catalog selections and connection orientations matter: a change can alter compartment size, bus transitions, wireway space or door features. Allow for specified wiring access and bending space rather than treating the enclosure as a shell independent of its contents.

For an accurate quote, submit the device list with manufacturer and catalog identifiers where selected, plus metering, control-power and communications requirements. Mark items still under engineering review. Identify incoming and outgoing conductor sizes and termination preferences when known. Final device selection and layout should be checked against the applicable drawings, electrical design and project requirements before release to production.

Drawing Review Before Release

Fabrication drawings translate the design into dimensions, component locations, structural details and connection interfaces. Review the lineup elevations, plan views, section details, cable entry points, bus arrangement and compartment access. Confirm that the drawing reflects the latest one-line diagram and room information, especially where field routing or adjacent equipment affects openings and clearances.

Return consolidated, clearly identified comments and indicate who is authorized to approve the drawings. Resolve discrepancies among specifications, schedules and drawings before production; uncoordinated revisions can affect fit, fabrication work and delivery planning. The manufacturer can assess buildability, while design adequacy and code compliance remain subject to the responsible engineer’s review and applicable utility or AHJ requirements.

Quote Inputs, Scope and Delivery Planning

A useful quote request includes equipment type, electrical ratings, lineup arrangement, drawings, device schedule, enclosure requirements, bus criteria, quantity and requested delivery destination. Add project milestones, submittal expectations, shipping constraints and known site limitations. Clearly separate mandatory requirements from options or open decisions so the scope can be evaluated without guessing at critical construction details.

U.S. manufacturing, domestic components, custom fabrication and nationwide shipping can be considered within the project’s supply plan; component origin and availability should be confirmed for the specific scope. Lead time depends on design maturity, component selection, approvals and production scheduling, so request a project-specific estimate. Confirm shipping configuration, receiving access and final installation interfaces with the project team.

PROJECT PARAMETERS

Details make
the difference.

Every project is different. Use these points as a starting place for a conversation about your requirements.

Discuss your specifications
SPECIFICATION OVERVIEW01 — 06
Project specification overview
Equipment & scopeDefined by project requirements
Voltage classConfirm for the application
Current ratingConfirm for the application
Applicable standardsUL 891 for applicable low-voltage switchboards; other standards per specification
ManufacturingMade in USA with American components
Lead timeQuoted per project

Final configuration, ratings, standards, and timing are confirmed with your quote.

LET'S GET TO WORK

Tell us what
you’re building.

Share the essentials and start a conversation about equipment for your project.