An automatic transfer switch monitors designated power sources and, when programmed conditions are met, commands a transfer of connected loads. Its sensing, timing and switching arrangement must suit the system.

01 / BUILT WITH PURPOSE SWITCHGEAR BUILDERS OHIO

Switchgear cabinets in an electrical equipment room
REPRESENTATIVE
EQUIPMENT
01
Made in USAAmerican manufacturing
02
UL 891 assembliesFor applicable low-voltage switchboards
03
Short lead timesTiming quoted per project

What an Automatic Transfer Switch Is

An automatic transfer switch, commonly abbreviated ATS, is equipment that connects a load to one of two or more power sources and changes the selected source automatically under defined control conditions. A common arrangement monitors normal utility power and an alternate source, such as an onsite generator, then initiates a transfer when its logic recognizes an unacceptable normal-source condition.

The ATS is not itself a generator, and it does not create power or guarantee uninterrupted service. It senses configured electrical conditions, applies programmed timing and transfer rules, and operates switching contacts or mechanisms. Whether a load experiences a brief interruption depends on the transfer method, source availability, equipment design and the characteristics of the connected load.

How Sensing and Control Logic Work

The controller evaluates inputs selected for the application. These may include voltage, frequency, phase condition, source availability and external signals, but the exact sensing scheme varies by equipment and specification. Setpoints and time delays determine when a condition counts as a failure, when an alternate source is acceptable, and when the switch is permitted to move.

After a normal-source failure is recognized, the control sequence may send a start signal to a generator and wait until the alternate source meets configured criteria. Once it is available, the ATS transfers the load. When normal power returns, retransfer may occur immediately or after a delay, followed by a generator cooldown sequence if the system is configured to provide one.

Transfer Methods and Load Continuity

An open-transition ATS disconnects one source before connecting the other, creating a break in load supply during transfer. This is a common arrangement, but the interruption may affect sensitive processes, controls or motor loads. The responsible engineer should evaluate load ride-through, restart behavior and coordination with uninterruptible power supplies or other power-conditioning equipment.

Closed-transition equipment can overlap sources briefly during a permitted transfer, subject to system design and utility requirements. It is not suitable for every installation and may require synchronism checks, protective measures and utility approval. Specify the intended transition method rather than assuming all automatic transfer switches provide the same continuity or operating sequence.

ATS Configurations and System Boundaries

Transfer equipment is selected around the sources and loads it serves. A typical system may place one ATS between a utility service and generator, while a facility with multiple essential-load groups may use separate transfer switches or a coordinated distribution arrangement. Confirm whether the ATS is service entrance equipment, downstream distribution equipment, or part of a larger switchboard or power system.

Source count, poles, neutral treatment, enclosure, bypass or isolation provisions, and control interfaces are application-specific. A switched neutral may be needed in some separately derived source arrangements; grounding and bonding must be evaluated for the actual design. Equipment integration and construction details should be confirmed for the proposed build, not presumed from the ATS label.

Ratings, Protection and Coordination

Selection requires more than matching nominal voltage and current. The engineer should establish the system voltage, phase, frequency, continuous load, expected load profile, available fault current and the required withstand or closing performance. The source protective devices, conductors and transfer equipment must be evaluated together for the installation’s fault and coordination requirements.

Motor starting, transformer inrush, nonlinear loads and load-step behavior can affect source acceptance and generator sizing. The ATS control sequence should be reviewed alongside generator controls, upstream protection and downstream distribution. Applicable product standards and listing requirements depend on equipment type and intended use; verify the specific construction and project requirements rather than assuming a rating or approval.

Operating Sequence and Site Conditions

A practical specification describes what the system should do during source failure, alternate-source startup, transfer, restoration and return to normal. Include desired delays, test operation, alarms, remote status points and any load-shed or retransfer requirements. These details help avoid conflicting assumptions among the electrical design, generator package, controls and facility operating procedures.

Installation conditions also matter. Confirm indoor or outdoor location, ambient temperature, enclosure needs, access for inspection and maintenance, cable entry direction, available working space and environmental exposure. The equipment layout should accommodate the actual conductors and termination approach. The responsible engineer and contractor should coordinate these constraints with the facility, utility and authority having jurisdiction where applicable.

Information to Provide for a Quote

For a new ATS quotation, provide the one-line diagram and identify each source, the load served, system voltage, phase, frequency and required current rating. Include available fault-current information, upstream overcurrent devices, neutral and grounding arrangement, transition method, and any required bypass, isolation or service-entrance configuration. Note applicable specifications and project standards.

Also share generator or alternate-source details, control and communication interfaces, preferred operating sequence, enclosure and installation conditions, cable and termination requirements, schedule, and shipping destination. Flag unusual loads, load management needs and utility conditions. A U.S. manufacturer can review the requested configuration and custom fabrication scope for a new build; final design suitability remains subject to project review.

Review Before Procurement and Installation

Before release, compare the proposed ATS submittal with the one-line diagram, sequence of operations, protective-device coordination and generator requirements. Check ratings, poles, neutral handling, control inputs, alarms, enclosure and connection details. Confirm the selected transition behavior matches the intended load continuity and any applicable utility rules or project specifications.

An automatic transfer switch is one component in a coordinated power system, not a substitute for engineering review or commissioning planning. The responsible engineer should verify the design, and the utility and AHJ should be consulted where their requirements apply. Clear documents and confirmed interfaces help contractors install and test the equipment according to the project intent.

PROJECT PARAMETERS

Details make
the difference.

Every project is different. Use these points as a starting place for a conversation about your requirements.

Discuss your specifications
SPECIFICATION OVERVIEW01 — 06
Project specification overview
Equipment & scopeDefined by project requirements
Voltage classConfirm for the application
Current ratingConfirm for the application
Applicable standardsUL 891 for applicable low-voltage switchboards; other standards per specification
ManufacturingMade in USA with American components
Lead timeQuoted per project

Final configuration, ratings, standards, and timing are confirmed with your quote.

LET'S GET TO WORK

Tell us what
you’re building.

Share the essentials and start a conversation about equipment for your project.

Prefer to talk?(951) 403-5738

Email our team at saleselectricalbuyers@gmail.com.

SWITCHGEAR BUILDERS OHIO
BUILT FOR THE WORK AHEAD

PROJECT INQUIRY

Request a quote

This form opens your email application where supported. Review and send your request to saleselectricalbuyers@gmail.com from your email app; nothing is submitted directly through this website.

* Required fields